Free 2021 Cisco and NetApp FlexPod NS0-176 dumps are available by DumpsTorrent [Q23-Q47]

Share

Free 2021 Cisco and NetApp FlexPod NS0-176 dumps are available on Google Drive shared by DumpsTorrent

Welcome to download the newest DumpsTorrent NS0-176 PDF dumps: https://www.dumpstorrent.com/NS0-176-exam-dumps-torrent.html ( 141  Q&As)

NEW QUESTION 23
An administrator is trying to present an NFS datastore to an ESXi host.
Which two must be available before mounting? (Choose two.)

  • A. datastore name case sensitivity
  • B. export policy access
  • C. junction path case sensitivity
  • D. host name case sensitivity

Answer: B,D

 

NEW QUESTION 24
Exhibit:

Referring to the exhibit, what do the asterisks on the left indicate about the output of the ~show zoneset active~ command?

  • A. Only a single path is present.
  • B. A redundant path is present.
  • C. The device is currently logged in.
  • D. The device is not currently logged in.

Answer: C

 

NEW QUESTION 25
Which two technologies must be deployed for a Cisco Nexus 9000 ACI design? (Choose two.)

  • A. LACP
  • B. spine switch
  • C. VSM
  • D. APIC

Answer: B,D

 

NEW QUESTION 26
In which two locations is the VSAN ID configured in a FlexPod solution? (Choose two.)

  • A. UCS Manager
  • B. hypervisor adapter
  • C. Nexus switches
  • D. Storage Virtual Machine

Answer: A,C

 

NEW QUESTION 27
Which type of pools do you need to create vHBA templates?

  • A. WWPN
  • B. MAC
  • C. WWNN
  • D. IQN

Answer: A

 

NEW QUESTION 28
Which three are characteristics of a NAS data LIF? (Choose three.)

  • A. It can be associated with an IP address.
  • B. It can be associated with an Ethernet port or VLAN interface.
  • C. It is associated with the management LIF.
  • D. It can be associated with a Fibre Channel port.
  • E. It can be associated with a WWPN
  • F. It is associated with the administrative Vserver.
  • G. It can be associated with an interface group (ifgrp).

Answer: A,B,G

 

NEW QUESTION 29
Exhibit:

Which Cisco switch is shown in the exhibit?

  • A. Nexus 5596
  • B. Nexus 5548
  • C. Nexus 2232
  • D. Nexus 7004

Answer: B

 

NEW QUESTION 30
Under which tab in UCS Manager would you create a boot policy?

  • A. SAN
  • B. Servers
  • C. Equipment
  • D. LAN

Answer: B

 

NEW QUESTION 31
When configuring a volume to contain a LUN, which administrative tool automatically applies NetApp recommendations?

  • A. Microsoft SystemCenter
  • B. Data ONTAP command-line interface
  • C. VMware vSphere
  • D. OnCommand System Manager

Answer: D

 

NEW QUESTION 32
You run NetApp ConfigAdvisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.
Which set of commands will correct this problem?

  • A. network interface modify- node netapp-01 -port e0a -flowcontrol -admin none network interface modify -node netapp-02 -port e0a -flowcontrol - admin none
  • B. network port modify- node netapp-01 port e0a-flowcontrol-admin full network port modify- node netapp-02 port e0a-flowcontrol-admin full
  • C. network interface modify- node netapp-01 port e0a-flowcontrol-admin full network interface modify- node netapp-02 port e0a-flowcontrol-admin full
  • D. network port modify -node netapp-01 -port e0a -flowcontrol-admin none network port modify -node netapp-02 -port e0a -flowcontrol-admin none

Answer: D

 

NEW QUESTION 33
Which is a valid connectivity option for a FlexPod?
Note some of these may also be 'valid' options outside of a FlexPod architecture but do not specifically meet FlexPod scalability and availability requirements.

  • A. UCS C-Series direct attach FAS
  • B. UCS B-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • C. UCS C-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • D. UCS B-Series direct attach FAS
  • E. UCS C-Series > Nexus 3048 < FAS
  • F. UCS B-series > UCS FI > 2232PP FEX > Nexus 5548 < FAS
  • G. UCS B-Series > UCS FI > Catalyst 3750 < FAS

Answer: C,E

 

NEW QUESTION 34
On a NetApp clustered Data ONTAP cluster, a volume named datastorel resides on an aggregate named node1 aggr1 and is mounted into the namespace at the junction path /esx cluster1/ds1.
A VMware virtual machine file named myhost.vmdk is at the root of the volume datastorel. A volume move operation relocates the datastorel volume to an aggregate named node3 aggr1.
In this scenario, what is the full path to the file myhost.vmdk after the volume move is complete?

  • A. /esx_cluster1/ds1/myhost.vmdk
  • B. /esx_cluster1/datastore1/myhost.vmdk
  • C. node3_aggr3/esx_cluster1/ds1/myhost.vmdk
  • D. /vo1/esx_cluster1/ds1/myhost.vmdk

Answer: A

 

NEW QUESTION 35
You are asked to install the Virtual Supervisor Module (VSM) software on a Nexus 1000v switch.
Which two sources would you use to install this software? (Choose two.)

  • A. PXE boot
  • B. VSC plug-in
  • C. ISO image
  • D. OVA file

Answer: A,C

 

NEW QUESTION 36
When creating a virtual machine in VMware vSphere 5.x, which type of virtual disk should be provisioned if you would like to fully pre-allocate storage with the highest chance of being contiguous?

  • A. Thin Provision
  • B. Thick Provision Eager Zeroed
  • C. Thick Provision Lazy Zeroed
  • D. Full Provision

Answer: B

 

NEW QUESTION 37
Which set of commands maps VLAN 100 to VSAN 100?

  • A. Nexus 5000-B# configure terminal Nexus 5000-B(config-vsan) # vlan 100 Nexus 5000-B (config-vsan)# vsan 100 name vsan100
  • B. Nexus 5000-A#configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-A (config)# vsan 100 Nexus 5000-A (config-vsan) # fcoe vsan 100
  • C. Nexus 5000-A#configure terminal Nexus 5000-A (config) # vlan 100 Nexus 5000- A (config-vlan_ #fcoe vsan 100
  • D. Nexus 5000-B# configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-B (config-vsan)# vsan 100 Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100

Answer: C

 

NEW QUESTION 38
Exhibit:

You are configuring iSCSI boot from SAN on your UCS blades.
Referring to the exhibit, how many paths will there be to the Boot LUN?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 39
Exhibit:

Which hardware component is shown in the exhibit?

  • A. FI
  • B. FEX
  • C. VIC
  • D. IOM

Answer: C

 

NEW QUESTION 40
You currently have a FlexPod Datacenter solution, and you are merging with another company. That company's environment currently has a mix of different Cisco servers. You want to add as many of those servers to your FlexPod solution as possible.
In this scenario, which two Cisco servers are supported in a FlexPod environment? (Choose two.)

  • A. S3260 M5
  • B. C480 ML M5
  • C. B200 M5
  • D. HX240c Edge M5

Answer: B,C

 

NEW QUESTION 41
Exhibit:

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 42
An administrator has a FlexPod solution using VMware vSphere 6.0. The ESXi hosts use iSCSI for storage connectivity, and all paths have been configured and connected between the NetApp cluster and the ESXi hosts.
Virtual Storage Console has been installed and ESXi host-recommended settings have been applied to all hosts. The active LUN path for one of the iSCSI datastores experiences a connectivity failure and the LUN switches to a new active path.
In this scenario, which event would trigger the ESXi host to switch the active LUN path again?

  • A. The ESXi host scans for new VMFS datastores.
  • B. The NetApp LIF is reverted to its home port.
  • C. The original LUN path comes back online.
  • D. The host processes 1,000 I/O operations.

Answer: B

 

NEW QUESTION 43
Click the Exhibit button.

On your NetApp storage system, you create a volume named datastore1, mount it to a junction path, and then set the correct export policy. When you attempt to mount the volume from VMware ESXi as a datastore, the server is unable to mount the path /datastore1. You verify that your existing NFS datastore (/datastore0) on the same NetApp storage system SVMis functioning normally.
Referring to the exhibit, what is preventing the server from mounting the new datastore?

  • A. The volume is too large to be mounted as an NFS datastore
  • B. The LIF needs to be at its home-port when the volume is mounted.
  • C. The load-sharing mirrors need to be updated.
  • D. Two volumes cannot be mounted using the same LIF IP address.

Answer: C

 

NEW QUESTION 44
How are jumbo frames enabled on the Nexus 5548?

  • A. system qosmtu 9216
  • B. system mtu jumbo 9000
  • C. system jumbo-frame
  • D. policy-map type network-qos JUMBOclass type network-qos class-defaultmtu 9216system qosservice-policy type network-qos JUMBO
  • E. policy-map type queueingclass type queueing class-defaultmtu 9216

Answer: D

 

NEW QUESTION 45
For a 'boot from SAN' configuration, which two features must be enabled? (Choose two)

  • A. FCOE
  • B. FC
  • C. NPIV
  • D. VPC
  • E. UDLD
  • F. FCSP

Answer: A,C

 

NEW QUESTION 46
Refer to the exhibit.

When configuring a Cisco UCS B-Series server to support boot from SAN in a FlexPod deployment, which statement is correct?

  • A. This configuration will support boot from SAN
  • B. Boot from SAN is not supported in a FlexPod environment
  • C. This given configuration will not support a local ESXi installation
  • D. This configuration will not support boot from SAN.

Answer: D

 

NEW QUESTION 47
......

Tested Material Used To NS0-176: https://www.dumpstorrent.com/NS0-176-exam-dumps-torrent.html