NEW QUESTION 11
Exhibit.

Referring to the exhibit, what would cause a customer to have an Issue with SVM eplc_fcp when mapping a namespace to a host?

  • A. FC switch zoning has not been done correctly.
  • B. NVMe Is not configured for the SVM.
  • C. FC has not been licensed on the cluster.
  • D. NVMe is not licensed on the cluster.

Answer: B

 

NEW QUESTION 12
Exhibit.

A user cannot save a file on an ONTAP SMB share.
Referring to the exhibit, which action allows the user to save the file?

  • A. Allow the file type *, rtf In the CIFS Server fpolicy.
  • B. Synchronize the ONTAP Cluster time to the Active Directory time.
  • C. Set the user permission for the share to write.
  • D. Let the user save the file to a writeable location.

Answer: D

 

NEW QUESTION 13
Exhibit.
Miss-----------------
The availability of the remote cluster in the peering relationship shows "Partial." Referring to the exhibit, what is the reason for this status message?

  • A. The remote cluster does not have its cluster license applied properly.
  • B. The Intercluster LIFs on the local cluster are unavailable and not able to communicate to the remote cluster.
  • C. The local cluster is unable to authenticate successfully to the remote cluster.
  • D. Some nodes In the local cluster are not able to contact some or all nodes in the remote cluster.

Answer: D

Explanation:
Some nodes in the local cluster are not able to contact some or all nodes in the remote cluster.
Partial - The peer cluster availability status will be Partial only if some nodes in the local cluster are not able to contact some or all nodes in the peer cluster. https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-cmpr-991/cluster__peer__show.html?cp=5_1_10_18_5

 

NEW QUESTION 14
Click the Exhibit button.
You are the administrator of your company's ONTAP 9.7 storage system. You try to connect your vSphere hosts to a newly created NFS datastore and receive the error message shown in the exhibit.
What must you do to solve this problem?

  • A. Activate all NFS protocol versions in your SVM.
  • B. Add the vSphere host's IP addresses to an export policy rule.
  • C. Change the volume security style to UNIX.
  • D. Set the MTU size for the data LIF to 9000.

Answer: C

 

NEW QUESTION 15
You want to add SSDs to existing HDD aggregates.
Which NetApp tool helps you to validate how many SSDs would Improve performance?

  • A. Active IQ Unified Manager
  • B. OnCommand Workflow Automation
  • C. ONTAP System Manager
  • D. Automated Workload Analyzer

Answer: C

 

NEW QUESTION 16
You are running a FAS system environment with hybrid and SSD aggregates. You want to free some space on the SSD drives by using FabricPool technology. You want to keep latency as low as possible.
In this scenario, which technology will accomplish this task?

  • A. on-premises StorageGRID
  • B. FlexCache
  • C. thick provisioning
  • D. Flash Pool

Answer: D

 

NEW QUESTION 17
Click the Exhibit button.
Only the hosts that are on the 10.1.100.0/24 network can access CIFS shares on SVM lab-fs1.
Referring to the exhibit, what would you do to allow hosts on other networks to access lab-fs1?

  • A. Increase the metric of the route with gateway 10.1.100.1.
  • B. Decrease the metric of the route with gateway 10.1.100.1.
  • C. Delete the route with gateway 192.168.106.1.
  • D. Create a SVM default route for 10.1.100.1.

Answer: D

 

NEW QUESTION 18
You created a thick-provisioned NAS volume. You receive an alert that the snapshot reserve is full.
In this scenario, which two actions will solve this problem? (Choose two.)

  • A. Increase the fractional reserve.
  • B. Increase the snapshot reserve percentage.
  • C. Decrease the volume size.
  • D. Delete Snapshot copies.

Answer: B,D

 

NEW QUESTION 19
Click the Exhibit button.
You are planning to present storage to your servers from your AFF system using the FC protocol. You have a pair of Fc switches to ensure connectivity and you have decided to use WWPN zoning.
Referring to the exhibit, which two WWPNs do you use for your configuration? (Choose two.)

  • A. fc-2 WWPN
  • B. 0d WWPN
  • C. 0c WWPN
  • D. fc-1 WWPN

Answer: A,D

 

NEW QUESTION 20
Exhibit.

A Linux host with the 10.0.1.24 IP address is unable to mount the VOL_A volume using NFSv3.
Referring to the exhibit, what is the problem?

  • A. The logical Interface does not allow the NFSv3 protocol.
  • B. The volume is in read-only.
  • C. The host IP address does not match the export policy rule.
  • D. The volume is not mounted In the namespace.

Answer: D

Explanation:
The volume is not mounted in the namespace. https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.cdot-famg-nfs%2FGUID-8E400D78-B405-4682-8F33-143783F2D580.html Even if the volume was read only it could be mounted - also the client IP is in the desired range and LIF is configured for NFS.

 

NEW QUESTION 21
A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)

  • A. You can convert the FlexVol volume to a FlexGroup volume.
  • B. A FlexVol to FlexGroup conversion is not supported.
  • C. Use XCP to copy data from a FlexVol to a FlexGroup.
  • D. Use SnapMirror to replicate data from FlexVol to FlexGroup.

Answer: B,C

 

NEW QUESTION 22
You are currently using SnapMlrror Synchronous (SM-S) to protect a critical workload at your organization and you want to convert the SnapMlrror policy from Sync to StrictSync.
In this scenario, which procedure allows you to achieve this task?

  • A. Modify the existing SnapMirror relationship specifying the strictsync policy, then promote It.
  • B. Modify the existing SnapMirror relationship specifying the strictsync policy, then re-synchronize It.
  • C. Recreate the SnapMlrror relationship, specifying the strictsync policy, then promote It.
  • D. Recreate the SnapMirror relationship, specifying the strictsync policy, then re-synchronize it.

Answer: C

 

NEW QUESTION 23
Click the Exhibit button.
You have an ONTAP cluster that is running a FlexGroup that is serving SMB data out to various users. One of the users receives an error when trying to modify an existing file.
What is the cause of the problem?

  • A. The constituent is full
  • B. The aggregate is full
  • C. The FlexGroup is full
  • D. The FlexGroup is offline

Answer: A

 

NEW QUESTION 24
Which security method would be used to authenticate targets and Initiators In an ISCSI environment?

  • A. /etc/hosts
  • B. CHAP
  • C. NIS
  • D. LDAP

Answer: A

 

NEW QUESTION 25
You are currently using SnapMlrror Synchronous (SM-S) to protect a critical workload at your organization and you want to convert the SnapMlrror policy from Sync to StrictSync.
In this scenario, which procedure allows you to achieve this task?

  • A. Recreate the SnapMlrror relationship, specifying the strictsync policy, then promote It.
  • B. Modify the existing SnapMirror relationship specifying the strictsync policy, then promote It.
  • C. Modify the existing SnapMirror relationship specifying the strictsync policy, then re-synchronize It.
  • D. Recreate the SnapMirror relationship, specifying the strictsync policy, then re-synchronize it.

Answer: D

Explanation:
KB included in the reference also confirms C is the correct answer. Here is another KB also confirming; https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.pow-dap%2FGUID-AE2302D3-E489-43FE-B64F-1D351DAC6787.html

 

NEW QUESTION 26
Click the Exhibit button.

Referring to the exhibit, a customer is experiencing performance problems on an SVM supporting NVMe/FC. You review the physical FC ports that are connected into the 32 Gbps switches for cluster tme-a700.
In this scenario, what is causing the performance problems?

  • A. Port 2b has two many LIFs running across the physical port.
  • B. Port 2a needs a 16 Gbps SFP+ installed.
  • C. Port 2a needs more network interfaces added to the physical port.
  • D. Port 2b has a 16 Gbps SFP+ installed.

Answer: D

 

NEW QUESTION 27
......


Network Appliance NS0-162 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Demonstrate knowledge of how to administer ONTAP performance
  • Describe how to use logical storage features
Topic 2
  • Describe inflight or at rest encryption
  • Describe high availability concepts
  • Describe how to use network components
Topic 3
  • Describe how to upgrade or scale ONTAP clusters
  • Describe how to manage Storage Virtual Machines (SVM)
Topic 4
  • Identify MetroCluster concepts
  • SAN Solutions and Connectivity
  • Describe how to use SAN solutions
Topic 5
  • Demonstrate knowledge of how to troubleshoot SAN solutions
  • Describe NetApp ONTAP Data Fabric solutions

 

100% Passing Guarantee - Brilliant NS0-162 Exam Questions PDF: https://www.dumpstorrent.com/NS0-162-exam-dumps-torrent.html

NS0-162 Dumps 2022 - NewNetwork Appliance Exam Questions: https://drive.google.com/open?id=1Iwi4jrzRUKd19tpCuqPz85byZztF7jI-